Incubation Time Matters in Cannabis Yeast and Mold Testing

Total yeast and mold (TYM) testing is one of the most controversial topics in cannabis safety testing. 

Currently, 33 jurisdictions require total yeast and mold (TYM) testing for at least one cannabis product type, and according to publicly available lab testing data from 21 different jurisdictions, TYM is also the leading cause of microbial testing failures.

Test Fails Tests Run Fail Rate
TYM 136,464 1,450,831 9.41%
Aspergillus (pooled, any species) 34,006 1,143,999 2.97%
Aspergillus spp. (CFU/g) 16,321 383,965 4.25%
BTGN 5,402 144,832 3.73%
TAC 4,162 290,819 1.43%
Total Coliforms 2,641 146,376 1.80%
Salmonella 157 712,913 0.02%
STEC 29 305,014 0.01%

There are several different methods to test for TYM, including culture-based methods and molecular methods such as qPCR. Unfortunately, the results from those methods do not always agree. In fact, research has shown that microbial testing methods not only disagree with each other, but they often disagree with themselves!

Of course, that assumes that labs are performing the methods according to the manufacturer’s specifications. At CannMed 26, a panel titled “Beyond Total Yeast and Mold: Towards Modern Risk-Based Microbial Standards” raised concerns that some cannabis labs are cutting incubation times short to decrease their turnaround times, which can lead to underreported TYM counts. 

Victoria Pretti of the New York State Office of Cannabis Management was a panelist, and she named time and temperature the biggest technical limitation of using plating for TYM.  “Who wants to wait 60 hours?” she said. “Sorry, you can’t get it in 48 hours.” An audience member responded that many labs do exactly that, reading rapid plates at 48 hours and incubating at 30°C.

For rapid plates, that’s a shorter window, at a temperature they were never validated for in cannabis. Below are the validated conditions, why an early read undercounts mold, and how different states have handled it.

What the Validations Actually Say

Three of the most widely used culture methods for TYM, Petrifilm Rapid Yeast and Mold plates, CompactDry, and TEMPO, all hold AOAC validations for dried cannabis flower (THC >0.3%). Only TEMPO is validated for a 48-hour read at 30°C, a condition AOAC added in January 2025. Petrifilm Rapid and CompactDry plates are validated for 60 to 72 hours at 25°C to 28°C, and 72 hours at 25°C. None of the three was validated in edibles, concentrates or hemp.

Method Validation Validated Incubation
Neogen (3M) Petrifilm Rapid Yeast and Mold AOAC Official Method 2014.05, cannabis flower extension (2022) 60–72 h at 25 ± 1°C or 28 ± 1°C
Hardy/Shimadzu CompactDry YMR AOAC PTM 092002, cannabis flower added through the 2021 emergency response validation 72 ± 3 h at 25 ± 1°C
bioMérieux TEMPO YM AOAC PTM 041001, cannabis flower added in 2021, and a 30°C condition added in 2025 72–76 h at 25 ± 1°C, or 48–52 h at 30 ± 1°C

Early Reads Miss Mold

Molds generally grow more slowly than yeasts, and some won’t form countable colonies within two days. Labs that read plates early undercount the organisms the test is meant to catch.

Food data shows how big the gap can be. In a Journal of Food Protection study of 56 food samples incubated at 25°C, 55% of Rapid YM plates showed no growth at 48 hours. By 72 hours, only 11% did. Those were food samples, not cannabis, but the biology of slow-growing molds is the same.

Temperature matters too. A 2021 study by RSR Analytical Laboratories compared Petrifilm Rapid plates on dried cannabis flower at 25°C and 28°C, both read at 60 to 72 hours. The 25°C plates gave statistically higher counts. If moving from 25°C to 28°C lowers counts, 30°C is further outside what the method was built for.

Plating also starts with a handicap. Panel moderator Sherman Hom noted that even the best plating methods recover only about half of what’s in a sample. Cutting the incubation short widens that gap.

How States Regulate Incubation Times

States take very different approaches. Some write an incubation time into the rules, some rely on validation and inspection, and many say nothing specific.

State What It Requires
Maine 18-691 C.M.R. ch. 5, § 6(10)(B)(1): yeast and mold samples "shall be incubated for a minimum of 72 hours, regardless of the technology used for analysis." Plating methods must also use an automated plate reader.
Colorado In January 2017, the Colorado Department of Public Health and Environment raised the Petrifilm yeast and mold incubation from 48 hours to 60–72 hours, concluding "48 hours is not a sufficient incubation period to obtain accurate results." Cultivators and manufacturers had to retest to confirm their process validations still held. Today, labs must also verify every method in house.
Nevada Nevada's guidelines call for 60–72 hours on Petrifilm Rapid plates, in line with the manufacturer's instructions.
Michigan R 420.305 requires "an optimized incubation period" for plating-based TYM methods, third-party validation for cannabis, and internal verification by the lab. It sets no number of hours.
New York The Office of Cannabis Management inspects labs with a team that includes a microbiologist. Per the panel, deviating from the manufacturer's instructions becomes a finding the lab must correct.

Rules only work if someone checks. On the panel, Heather Krug of Colorado’s health department noted that many states have no scientific staff inspecting labs at all.

Massachusetts shows what can happen when TYM results drift unchecked, though for a different reason. In June 2025, the Cannabis Control Commission suspended Assured Testing Laboratories’ license over a “pattern of failing to accurately report Total Yeast and Mold test results.” The lab reported a 0.05% TYM fail rate against a state average of 4.5%. The case was about reporting, not incubation, but it shows how far a lab’s results can drift from the rest of the market before a regulator steps in. The lab has disputed the findings and filed suit.

When a Clean Plate is Temporary

Early reads are a bigger concern for remediated flower. A recent McGill University study on irradiated cannabis found that after irradiation, bacteria were gone. Fungi didn’t appear during the first 60 hours of incubation, then returned by 120 hours at roughly pre-treatment levels. Mycotoxins, including T-2 toxin, were still present.

Irradiation can delay fungal growth on the plate without getting rid of the fungi. A remediated sample read at 48 hours could look clean while viable mold and its toxins remain in the product.

Same-Day Results without Waiting on colonies

The pressure behind early reads is easy to understand. Cultivators want product released, and two to four days is a long time to hold a batch. But the fix for slow results is a faster validated method, not a shortened slow one.

The PathoSEEK® platform from Medicinal Genomics uses qPCR, which is widely used for safety testing in both the cannabis and food industries. Instead of waiting for organisms to grow into visible colonies, qPCR detects their DNA directly, so results come back the same day.

  • AOAC certified. The PathoSEEK Total Yeast and Mold Detection Assay holds AOAC Performance Tested Methods certification (No. 062401) for detecting and enumerating total yeast and mold in dried cannabis flower.
  • Built for sensitivity. The assay targets the ITS region of the fungal genome, which appears in many copies per cell, roughly 20 in yeasts and 50 to 100 in molds.
  • No growth window to cut short. Slow-growing molds don’t need two to four days to show up, so there’s no temptation to read the result before it’s ready.

One caveat for remediated flower: qPCR detects DNA whether or not the organism can still grow. The kit includes a step to remove free DNA; however, Medicinal Genomics still recommends confirming viability with an approved plating method when a remediated sample comes in over the action limit.

What Labs Can Do Now

  • Incubate for the validated time and temperature: 60 to 72 hours at 25°C to 28°C for Petrifilm Rapid plates, and 72 hours at 25°C for CompactDry YMR. TEMPO’s 48-hour, 30°C condition applies only to TEMPO, not to plates.
  • Verify methods in house, competitor organisms included, even when the kit maker has already validated in a cannabis matrix.
  • Treat a passing TYM result on remediated flower with caution, especially if the plate was read early.
  • When turnaround time is the pressure, use a method that’s fast by design, like PathoSEEK, instead of cutting a culture method short.

A TYM result is only as reliable as the conditions behind it. If a plate was called at 48 hours, the number on the certificate of analysis may say more about the clock than about the product.

Watch the full panel, “Beyond Total Yeast and Mold: Towards Modern Risk-Based Microbial Standards,” from the CannMed 26 Innovation & Investment Summit on YouTube.

Share :

Have questions? Our experts are here for you

Our genetics-based cannabis testing and breeding technologies can help growers, dispensaries and labs grow cleaner, faster and healthier in every way. Because you’re not just delivering a product. You’re building a business. And a reputation.

MaGiC™ Lysis

Simplified DNA Extraction Process

SenSATIVAx®

Purify Plant and Microbial DNA

Grim Reefer®

Eliminate Dead DNA

PathoSEEK®

qPCR Detection Assays

PathoSEEK® ID

Identify Species in Failed Samples

FemINDICAtor®

Plant Sex Detection Assay

Mic & Myra

Automated Liquid Handling & qPCR

LIDAR

Breakthrough Multiplex Technology

Sequencing

Valuable Insights and Actionable Data

Fill form to watch Video